{"id":270,"date":"2022-02-03T15:17:32","date_gmt":"2022-02-03T14:17:32","guid":{"rendered":"http:\/\/au.feri.um.si\/leoss\/?p=270"},"modified":"2026-03-13T14:35:04","modified_gmt":"2026-03-13T13:35:04","slug":"all-fiber-low-cost-single-point-and-quasi-distributed-evanescent-field-temperature-sensors-with-extended-temperature-measurement-range-based-on-standard-telecommunication-graded-index-fibers-2","status":"publish","type":"post","link":"https:\/\/au.feri.um.si\/leoss\/en\/all-fiber-low-cost-single-point-and-quasi-distributed-evanescent-field-temperature-sensors-with-extended-temperature-measurement-range-based-on-standard-telecommunication-graded-index-fibers-2\/","title":{"rendered":"All-fiber, low-cost single-point and quasi-distributed evanescent field temperature sensors with extended temperature measurement range, based on standard telecommunication graded index fibers"},"content":{"rendered":"<p>Fiber-optic single-point and quasi-distributed evanescent temperature sensors recoated with a blend of poly(methyl methacrylate) and poly(vinylidene fluoride) are proposed. Solid cladding enables the construction of small-size, low-cost, relatively wide-range and fast-response temperature sensors. The diameter of the sensor does not exceed the dimensions of the original optical fiber, while the response time of the sensor is 7:4ms. Different mass ratios of polymers in the blend enable fine tuning of the applied cladding&#8217;s refractive index. This allows the construction of sensors for different temperature ranges, while the application of all-silica graded-index multimode fibers enables the construction of quasidistributed sensor systems with considerably reduced cross talk.<\/p>\n\n\n\n<p><a href=\"https:\/\/doi.org\/10.1364\/AO.47.004212\">https:\/\/doi.org\/10.1364\/AO.47.004212<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Fiber-optic single-point and quasi-distributed evanescent temperature sensors recoated with a blend of poly(methyl methacrylate) and poly(vinylidene fluoride) are proposed. Solid cladding enables the construction of small-size, low-cost, relatively wide-range and fast-response temperature sensors. The diameter of the sensor does not <a href=\"https:\/\/au.feri.um.si\/leoss\/en\/all-fiber-low-cost-single-point-and-quasi-distributed-evanescent-field-temperature-sensors-with-extended-temperature-measurement-range-based-on-standard-telecommunication-graded-index-fibers-2\/\" class=\"read-more\">Read More &#8230;<\/a><\/p>","protected":false},"author":7,"featured_media":1292,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[23,13,11,21],"tags":[],"_links":{"self":[{"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/posts\/270"}],"collection":[{"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/comments?post=270"}],"version-history":[{"count":2,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/posts\/270\/revisions"}],"predecessor-version":[{"id":558,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/posts\/270\/revisions\/558"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/media\/1292"}],"wp:attachment":[{"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/media?parent=270"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/categories?post=270"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/au.feri.um.si\/leoss\/en\/wp-json\/wp\/v2\/tags?post=270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}